Key | Type | Description | ||
MaxSigma | DWORD | Maximum deviation. Higher deviation will invalidate the read touch-samples. If using noisy displays, it might help to increase this value. | ||
InitSamples | DWORD | How many samples to ignore after touch-press. | ||
PressureL | DWORD | Low pressure (0..65536), Default=12. Value at which touch-pen up is detected. (UCB1400-Codec) | ||
PressureH | DWORD | High pressure (0..65536), Default=31. Value at which touch-pen down is detected. (UCB1400-Codec) | ||
WolfsonPressureH | DWORD | Pressure at which a touch-pen down is detected. Default: 260. Higher-values = More sensitive. | ||
ArraySize | DWORD | Number of samples to take to determine average value. | ||
SyncWithHsync | DWORD | Set to 0. Option to synchronize measurement with HSync of display. | ||
VRefBypass | DWORD | Set to 0. Use to enable external reference-voltage. | ||
InhibitIdle | DWORD | Inhibit idle, if touch is pressed. If the touch is sensitive against change of current consumption, setting this might help | ||
SampleDelay | DWORD | Number of micro-seconds to wait after each sample | ||
OldScale | DWORD | Set to 0. Used to scale touch-values, like it was done on the older version of this driver. | ||
SampleTimer | DWORD | Sample-Frequency (Trizeps2+3 only): Expressed in number of system-ticks (3686400 Hz). Trizeps4+5: in us | ||
DisableFilter | DWORD | Disable ADC filter if set to 1 | ||
REG78h | DWORD |
|
See Also
Connect a 4-wire Touch to a Trizeps,
Connect a 5-Wire Touch Panel to the Trizeps 4-wire Touch Controller