    In Windows Embedded CE6 InterruptDone is only callable from kernel-space. The function OEM_InterruptDone is a workaround to use InterruptDone from user-space.
    This function signals to the kernel that interrupting processing has been completed.
    See Platform-Builder-Help for details.

    VOID OEM_InterruptDone( DWORD idInt );

    Parameters

    idInt
    [in] Identifier of an interrupt.

    Return Values

    None.

    Requirements

    OS Versions: Windows Embedded CE 6.
    Header: drvlib_app.h
    Link Library: drvlib_app.lib
    added: 14.03.2008