Carrier-COMe-C96
Depending on the configuration and following revisions, the features of the board are subject to change. For detailed information on hardware specifications, please visit www.seco.com
This carrier is contained in the development kit DEV-KIT-COMe-T6
INDEX
How can I configure jumpers?
Component | Description | Use | Default configuration (Fig.1) |
---|---|---|---|
CN11 |
| Set jumper 1-2 for TYPE mode Set jumper 2-3 for no TYPE/AT mode | 1-2 Plugged |
J2 |
| Set jumper 1-2 for ATX mode | 1-2 Plugged |
CN6 |
| Set jumper 1-2 for battery disconnected | 2-3 Plugged |
JP2 |
| Set no jumper for | Plugged |
JP12 | PANEL BACKLIGHT VOLTAGE SELECTION | Set jumper1-2 for 12V | 2-3 Plugged |
JP13 | PANEL VDD VOLTAGE SELECTION | Set jumper 1-2 for 5V | 2-3 Plugged |
JP11 | PANEL INTERFACE SELECTION | Set jumper for eDP | Unplugged |
JP8 | BIOS_DIS1 | Set JP8 and no JP7 for SPI on carrier | Unplugged |
JP7 | BIOS_DIS0 | Unplugged | |
JP10 | GPIO/SD | Set no jumper for GPIO | Plugged |
JP5 | COM1 | Set no jumper for RS-485 | Unplugged |
JP6 | COM2 | Set no jumper for RS-485 | Unplugged |
JP4 | ESPI/LPC# SELECTION | Set jumper for switch enabled | Plugged |
JP3 | ESPI/LPC# SELECTION | Set jumper for LPC from CEXP Set Set no jumper for ESPI from CEXP | Plugged |
JP14 | MIC#_SEL | Set no jumper for MIC2 | Plugged |
JP9 | 3-WIRES/4-WIRES FAN TACH DRIVER | Set jumper 1-2 for 4-wires fan | 1-2 Plugged |
JP1 |
| Set jumper for BATLOW# enabled | Unplugged |
CN3 |
| Set jumper 1-2 for PSU PWR_OK | 1-2 Plugged |
Fig. 1: Description of possible jumpers configuration
What to connect and where?
Further information about placement and description of connectors are available here.