Carrier-COMe-T6-E10
Depending on the configuration and following revisions, the features of the board are subject to change. For detailed information on hardware specifications, please visit www.seco.com
You can find all information regarding this COMexpress carrier board in the comprehensive Hardware Manual.
INDEX
How can I configure jumpers?
Component | Description | Use | Default configuration (Fig.1) |
|---|---|---|---|
CN11 |
| Set jumper 1-2 for TYPE mode Set jumper 2-3 for no TYPE/AT mode | 1-2 Plugged |
J2 |
| Set jumper 1-2 for ATX mode | 1-2 Plugged |
CN6 |
| Set jumper 1-2 for battery disconnected | 2-3 Plu |
JP2 |
| The power consumption on +5V_ALW can be monitored by removing 2 way jumper JP2 and inserting a tester set as a meter. | Plugged |
CN3 |
| Set jumper 1-2 for PSU PWR_OK | 1-2 Plugged |
JP12 | PANEL BACKLIGHT VOLTAGE SELECTION | Set jumper1-2 for 12V | 2-3 Plugged |
JP13 | PANEL VDD VOLTAGE SELECTION | Set jumper 1-2 for 5V | 2-3 Plugged |
JP11 | PANEL INTERFACE SELECTION | Set jumper for eDP | Unplugged |
JP8 | BIOS_DIS1 | Set JP8 and no JP7 for SPI on carrier | Unplugged |
JP7 | BIOS_DIS0 | Unplugged | |
JP10 | GPIO/SD | Set no jumper for GPIO | Plugged |
JP5 | COM1 | Set no jumper for RS-485 | Unplugged |
JP6 | COM2 | Set no jumper for RS-485 | Unplugged |
JP4 | ESPI/LPC# SELECTION | Set jumper for switch enabled | Plugged |
JP3 | LPC_RST# | when jumper JP3 is inserted, this signal is derived by CB_RESET# signal or simply by biasing it using a Ultra High Speed CMOS buffer. When jumper JP3 is not inserted, this signal is derived by an eSPI to LPC bridge placed on carrier board | Plugged |
JP14 | MIC#_SEL | Set no jumper for MIC2 | Plugged |
JP9 | 3-WIRES/4-WIRES FAN TACH DRIVER | Set jumper 1-2 for 4-wires fan | 1-2 Plugged |
JP1 |
| Set jumper for BATLOW# enabled | Unplugged |
What to connect and where?
Further information about placement and description of connectors are available here.